Osseodensification Burs Kit Saw Disk

The recently introduced technique of Osseodensification Burs Kit Saw Disk  for dental implant involves the use of special drills  run in a counter-clockwise direction at the Osteotomy site. It is claimed that this causes expansion of the osteotomy site, and increases density of the bone in immediate vicinity of the Osteotomy. We reviewed published papers on the primary stability attained using this drilling technique. As a secondary finding, the bone to implant contact  and the bone area fraction occupancy  was also compared between the conventional drilling protocol and the Osseodensification protocol, among these articles. A Systematic search was performed in PubMed-Medline, Embase and Google Scholar for clinical/animal studies up to November 2018. A total of 12 articles, from a database  articles, consisting of 8 animal histologic studies, 2 human based clinical studies, 1 case series and 1 case report were assessed. 10/12 articles measured the insertion torque values, 7/12 articles measured the BIC and 6/12 articles estimated between the two techniques. Quality assessment of 8 studies performed using ARRIVE guidelines showed that 6/8 studies had a high score. An average increase in the insertion torque, was noted in the Osseodensification group as compared to the conventional drilling group. Since most of these studies are non-clinical, it can be inferred that Osseodensification is an efficient way to enhance primary stability of implants in low density bone in an animal model.

  • Description
  • Additional information

Description

Osseodensification Burs Kit Saw Disk

The recently introduced technique of Osseodensification Burs Kit Saw Disk for dental implant involves the use of special drills  run in a counter-clockwise direction at the Osteotomy site. It is claimed that this causes expansion of the osteotomy site, and increases density of the bone in immediate vicinity of the Osteotomy. We reviewed published papers on the primary stability attained using this drilling technique. As a secondary finding, the bone to implant contact  and the bone area fraction occupancy  was also compared between the conventional drilling protocol and the Osseodensification protocol, among these articles. A Systematic search was performed in PubMed-Medline, Embase and Google Scholar for clinical/animal studies up to November 2018. A total of 12 articles, from a database  articles, consisting of 8 animal histologic studies, 2 human based clinical studies, 1 case series and 1 case report were assessed. 10/12 articles measured the insertion torque values, 7/12 articles measured the BIC and 6/12 articles estimated between the two techniques.

New 18 Pcs Surgical Drills kit include set of different drills head and their sizes associated tools, each set specialized for a unique purpose of dental jaw surgery. The kit is specially design with different tools, creating a quickest, easily to use for dental implant surgery.

The Kit Includes 18 Pcs:

MI -1525  2.0 mm

MI -2535  3.0 mm

MI -3545  4.0 mm

MI -4555  5.0 mm

MV -1828  2.3 mm

MV -2838  3.3 mm

MV -3848  4.3 mm

MV -4858  5.3 mm

MS -2228  2.5 mm

MS -3238  3.5 mm

MS -4248  4.5 mm

MS  -5258  5.5 mm

1 x Poilt Drill 1.8 mm

2 x Parallel Pin (Long & Short)

1 x Drill Extander

1 x Saw Disk 7.0mm

1 x Saw Disk 10.0mm

1 x Stainless Steel Organizer Box

Product Quality:

Manufactured from High Quality Medical Grade Stainless Steel.

100% Brand New & High Quality.

100% Customer Satisfaction Guaranteed.

Ultrasonic Cleaned

QC Passed: Yes

 

Additional information

Weight 0.5 kg